119 – C1 LATERAL MASS SCREW FIXATION IN CHILDREN: INDICATIONS, OUTCOMES, AND TECHNIQUE IN 11 CONSECUTIVE PATIENTS



Abstract

Purpose: Upper cervical spine stabilization in children can be challenging due to anatomic abnormalities such as incomplete posterior elements, vertebral artery variability and small patient size. Several techniques have been described for stabilization of the upper cervical spine, each with its own advantages and disadvantages. Since the introduction of the technique by Harms, many authors have shown C1 lateral mass screws to be safe and effective in the stabilization of the upper cervical spine in adults. No large series of paediatric C1 lateral mass screw fixation has been reported in the literature. The purpose of this study was to describe the indications, technique, and outcomes of C1 lateral mass screw fixation in a consecutive series of 11 paediatric patients.

Method: A database generated retrospective review of all patients who underwent C1 lateral mass screw fixation as part of an upper cervical spine stabilization construct was performed. In all patients the C2 dorsal root ganglion was sacrificed. Patient demographics and clinical outcomes were obtained through chart review. Radiographs immediately post-operatively, at six-weeks, three-months, and final follow-up were reviewed.

Results: Eleven consecutive paediatric patients underwent bilateral C1 lateral mass screw fixation for a variety of conditions including C1-C2 instability, deformity, congenital malformation, trauma, as well as revision surgery. The average age was 10 years (range 4 to 16 years) with a mean follow-up of 11 months (range 6 – 18 months). There were no iatrogenic vertebral artery, hypoglossal nerve or spinal cord injuries. All 11 patients had solid fusion clinically and radiographically, with no loss of fixation. The C2 dorsal root ganglion was sacrificed in all patients with resulting minor occipital parasthaesia that progressively diminished in severity.

Conclusion: This is the largest series of consecutive patients reported in the literature to date showing that the technique is safe and effective, with acceptable morbidity when applied to the paediatric population. We believe that C1 lateral mass screws offer significant advantages over traditional fixation techniques when the C1 vertebra is to be included in an upper cervical instrumented construct.

Correspondence should be addressed to: COA, 4150 Ste. Catherine St. West Suite 360, Westmount, QC H3Z 2Y5, Canada. Email: meetings@canorth.org