Purpose: Component malrotation is a recognized cause of post total knee arthroplasty (TKA) pain. The objective of this study was to evaluate the functional outcomes of TKA revision for component malrotation, and to compare it to revision surgeries for aseptic loosening as a control comparison group.

Method: Twenty four patients who had TKA revision due to component malrotation as the only objective abnormality were reviewed. Only patients with preoperative computerized tomography (CT) documentation of 3° or more malrotation of at least one of the components were included. Mean combined rotation was 6.8° (range, − 12 − 3) excessive internal rotation. Twenty four matched control patients had TKA revision due to aseptic loosening.

Results: Mean follow up was 37 months (range, 24–65). Mean interval from index surgery was 41 months (range, 24–65) for the study group and 98 months (range, 11–222) for the control group (p=0.0003). Preoperative Knee Society Score (KSS) improved by 49 points (range, 16–80) at 6 months postoperatively for the malrotation patients and by 39 (range, − 7–78) for the loosening patients (p=0.08). At last follow-up, KSS was 80 (range, 60–89) for the malrotation group and 75 (range, 26–90) for the loosening group (p=0.14).

Conclusion: We recommend the use of CT scans in evaluation of all patients with early painful TKA’s and no objective evidence of infection. When component malrotation is demonstrated, we believe the results of this study validate consideration of early revision.