KINEMATIC ASSESSMENT OF HIP MOVEMENT WHEN RETRIEVING AN OBJECT FROM THE FLOOR IN NORMAL SUBJECTS AND ARTHROPLASTY PATIENTS



Abstract

Introduction: The aim of this study was to compare hip movement between normal subjects and patients with a large Metal on Metal hip replacement, undertaking the task of retrieving an object from the floor.

Methods: An electromagnetic tracker was used to measure movement as subjects retrieved an object with flexed hips and straight knees. Measurements were taken from a control group of 10 subjects with bilaterally normal hips, and 10 subjects with unilateral hip replacement. Sensors were attached over the iliac crest and the mid-shaft of the lateral thigh. Data was collected as each subject repeated the movement 3 times. The tracker recorded data at 10 hertz, with an accuracy of 0.15 degree.

Results: For the normal group the mean hip flexion was 90.8 degrees (SD 20.1). For the arthroplasty group the mean flexion on the normal and operated sides were 74.0 (SD 21) and 72.7 degrees (SD 21) respectively. This was not significant (P= 0.83). However there was a significant difference in hip movement between the operated hips and those in the normal control group (P= 0.03).

For the bilaterally normal group the mean hip rotation was 2.9 degrees internal (SD 11.8). For the arthroplasty group the mean rotation on the normal and operated sides were 9.4 degrees external (SD 9.5) and 6.9 degrees internal (SD 13.9) respectively. In this group there was a significant difference between the normal and operated side (P= 0.02).

Discussion: This study has shown that patients with a unilateral hip replacement have no significant flexion difference between hips, when retrieving an object from the floor. However there was a significant difference compared to a control group with normal hips. A significant difference was also observed when comparing the rotation of an operated hip joint to the contra-lateral normal hip in the same individual.

Correspondence should be addressed to: British Hip Society, 35–43 Lincoln’s Inn Fields, London, WC2A 3PE, England. Email: c.wilson@boa.ac.uk