THE BASAL OPENING WEDGE OSTEOTOMY FOR HALLUX VALGUS, DOES IT WORK?



Abstract

Introduction: An osteotomy in the proximal first metatarsal corrects the metatarsal head position with much less movement of the fragment than an equivalent distal osteotomy. Most described techniques are technically demanding and reported complications including non-union, mal-union and transfer pain. We present our results of an opening wedge osteotomy with a medial wedge plate. We also present the pitfalls and tips to avoid complications.

Materials and Methods: Thirty-four procedures in 30 patients were performed using the Arthrex wedge plate. Demographic and clinical data, AOFAS scores and radiological measurements of standardised radiographs were collected for all the patients.

Results: All patients were females. The average age was 52 years. Twenty-seven were primary procedures and 7 patients had had previous, failed 1st ray surgery. No bone graft was used. Thirty-two feet showed clinical and radiological signs of union. Four complications occurred and one was treated with metatarsophalangeal joint fusion. One had an infection. Two patients had broken screws. The average hallux valgus angle and inter-metatarsal angle corrections were 200 and 90 respectively. Average increase in AOFAS scores: preoperative 47 to postoperative 81.

Discussion: The spacer in the plate acts as a pillar and obviates the need for a bony strut. Keeping an intact lateral cortex and preventing any shaft displacement was important in avoiding transfer pain. 4.5mm or smaller plates appear to have fewer problems and better scores, al though this was statistically unproven. Screw breakage in the absence of infection had no bearing on overall outcome. Some patients with poor fixation may benefit from non-weight bearing for the first 6 weeks.

Conclusion: The wedge plate osteotomy is a powerful tool to correct moderate to severe hallux valgus. It does not need additional bone graft and has a favorable clinical and radiological outcome. The prelude to optimum result was meticulous technique avoiding the discussed pit falls.

Correspondence should be addressed to: Mr Andrew H. N. Robinson, Editorial Secretary, Department of Trauma and Orthopaedics, BOX 37, Addenbrooke’s Hospital, Cambridge CB2 2QQ, England.