Full Access

A1018. EFFECT OF SURGICAL APPROACH ON GAIT FOLLOWING TOTAL KNEE ARTHROPLASTY



Abstract

Total knee arthroplasty (TKA) is a common surgery to relieve knee pain and increase range of motion due to osteoarthritis (OA) in older patients. Minimally invasive, computer navigated techniques are gaining popularity for knee replacement surgery. These techniques may have potential to provide better functional outcomes over a shorter period of time. Little data exists comparing the early functional recovery of patients following total knee replacement surgery performed using various common approaches. This study compares the functional gait of patients two months after surgery performed using one of four common approaches to determine if differences exist in the immediate recovery. This knowledge will aid surgeons determine the best approach to use when performing surgery.

This study was approved by the appropriate Institutional Review Board. Subjects volunteered to participate in the study and signed informed consent prior to testing. Subjects were excluded if the had significant diseases of the other joints of the lower extremity or a diagnosed disorder with gait disturbance. Patients were randomly assigned to receive unilateral primary TKA using standard parapatellar, mini-parapatellar, mini-midvastus, or mini-subvastus approaches. All patients received the same preoperative, perioperative, and postoperative critical pathways and standard orders. All incisions were five inches and all patients and examiners blinded to type of approach. Surgery was performed by one of two fellowship trained orthopedic surgeons. Patients visited the gait laboratory two months after receiving TKA. Motion data was captured using a ten-camera motion capture system (Motion Analysis Corp., Santa Rosa, CA). Three-dimensional force data was recorded using four floor embedded force platforms (AMTI Inc., Watertown, MA). Patients were asked to walk at a self selected speed along a 6.5 metre walkway. A minimum of five good foot strikes for each limb were recorded. Data were collected using EVaRT 5 software (Motion Analysis Corp., Santa Rosa, CA) and analyzed using OrthoTrak 6.2.8 (Motion Analysis Corp., Santa Rosa, CA) and MatLab software (The Mathworks Inc., Natick, MA). Statistical analysis was performed using SPSS 14.0 software (SPSS Inc., Chicago, Il) (α = 0.05).

Fifty-two patients (72 ± 6 years) volunteered to participate in the study. The approaches used were: standard parapatellar – 12; mini-parapatellar – 12; mini-midvastus – 14; mini-subvastus – 14. Statistical analysis found no significant differences in any of the variables measured except minimum knee flexion angle during stance (p=.046). The variables measured included the maximum and minimum injured lower limb joint angles in all planes during both stance and swing phase of gait. Also measured were the maximum joint moments in all planes during stance and hip, knee, and ankle powers.

Patients who received TKA using the mini-subvastus approach had greater knee extension through much of the single stance phase of the gait cycle which contributed to a lower (but not significant) peak knee flexion moment. These patients also had the highest ground reaction shear forces with higher ankle power absorption at foot strike and generation at push off. Mini-subvastus patients used a higher cadence to walk with a greater velocity then patients who received surgery using the other approaches.

The results of this study show only minor differences in gait between patients who have received surgery using the different approaches. The limited numbers of patients in the study and the large variation in outcomes so soon after surgery mean that in most cases the differences that were measured do not reach significant level. This study shows that the surgical approach used to implant the device has no apparent effect on the ability of the person to ambulate following surgery, however further study with increased numbers of patients and observation over a longer period of time will allow a stronger conclusion. The knowledge gained from this and future studies will enable surgeons to make decisions on type of approach based on factors other than expectations of functional outcome.

Correspondence should be addressed to Diane Przepiorski at ISTA, PO Box 6564, Auburn, CA 95604, USA. Phone: +1 916-454-9884; Fax: +1 916-454-9882; E-mail: ista@pacbell.net

Acknowledgements: support for this study was provided by Stryker