Full Access

A1137. METAL IONS IN CONJUNCTION WITH PATIENT ACTIVITY: HIP RESURFACING PATIENTS AT VARIOUS STAGES OF FOLLOW UP



Abstract

Evidence with respect to conventional hip arthroplasties suggests that device wear is related to patient activity rather than duration of usage. Activity level questionnaires appear to suggest that subjects with resurfacing arthroplasties continue to remain active after the procedure. However there is a paucity of objective evidence relating to the step rates of these patients in their daily lives and its effect on metal ions generated. The aim of this investigation is to assess

  1. the activity levels of hip resurfacing patients as follow up progresses and

  2. if there is any correlation between activity and metal ions generated.

Twenty-five consecutive male patients (average age 56 years) who underwent a unilateral 50 mm diameter hip resurfacing carried out by a single surgeon (DJWM) were recruited after informed consent. Patient step activity (Step Activity Monitor, SAM, Cymatech. Seattle WA, USA) was recorded at 1, 2, and 4-year follow-up stages and at the same time patient whole blood samples were collected and analysed using High Resolution Inductively Coupled Mass Spectroscopy (HR-ICPMS).

All patients in this study had well functioning hips at the four year follow up stage. All femoral components implanted were within the desired range of neutral to 10°. The mean acetabular component inclination angle was 42° (33° – 55°). Patient overall step activity remains unchanged up to the 4-year follow-up period.

At one year follow up, the whole blood cobalt and chromium concentrations show no correlation to mean number of steps taken per day by each patient (r2=0.02).

The correlation between whole blood cobalt and chromium concentration versus a function of body weight and peak index is not significant (r2=0.11).

This study provides objective evidence of the activity rates of patients at different stages of follow-up after a MoM surface replacement arthroplasty. It should be emphasised that the walking speeds of these patients on average was significantly slower than 1 Hz, which is generally used in laboratory hip simulator studies.