header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

ACCURACY OF COMPUTER-ASSISTED NAVIGATION FOR FEMORAL HEAD RESURFACING DECREASES IN HIPS WITH ABNORMAL ANATOMY



Abstract

Correct positioning of the femoral component in resurfacing hip arthroplasty (RHA) is an important factor in successful long-term patient outcomes. Computer-assisted navigation (CAS) shows potential to improve implant positioning and possibly prolong survivorship in total hip and knee arthroplasty. The purposes of CAS systems in resurfacing the femoral head are to insert the femoral head and neck guide wire with greater accuracy and to help in sizing the femoral component, thus reducing the risk of notching of the head and neck junction. Several recent studies reported satisfactory precision and accuracy of CAS in RHA. However, there is little evidence that computer navigation is useful in the presence of anatomical deformities of the proximal femur, which is frequently observed in young patients with secondary degenerative joint disease.

The purpose of this in-vitro study was to determine the accuracy of an image-free resurfacing hip arthroplasty navigation system in the presence of two femoral deformities: pistol grip deformity of the head and femoral neck junction and slipped upper femoral epiphysis deformity. An artificial phantom leg with a simulated hip and knee joint was constructed from machined aluminum. Implant-shaft angles for the guide wire of the femoral component reamer were calculated, in frontal and lateral planes, with both a computer navigation system and an electronic caliper combined with micro-CT.

With normal anatomy we found close agreement between the CAS system and our measurement system. However, there was a consistent disagreement in both the frontal and lateral planes for the pistol grip deformity. Close agreement was found only on the frontal plane angle calculation in the presence of the slipped upper femoral epiphysis deformity, but calculation of the femoral head size was inaccurate.

This is the first study designed to assess the accuracy of a femoral navigation system for resurfacing hip arthroplasty in the presence of severe anatomical deformity of the proximal femur. Our data suggests CAS technology should not be used to expand the range of utilisation of resurfacing surgery, but rather to improve the surgical outcome in those with suitable anatomy.

Correspondence should be addressed to: Associate Professor N. Susan Stott, Orthopaedic Department, Starship Children’s Hospital, Private Bag 92024, Auckland, New Zealand.