header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

063 FRACTURES OF THE RADIAL HEAD AND DISRUPTION OF THE INTEROSSEOUS COMPLEX. IS THE RECONSTRUCTION POSSIBLE?



Abstract

In Essex-Lopresti injuries, the prevailing concept, according to which the stability of the forearm can be restored after fixation of the fracture or replacement of the radial head by a metallic implant, is disputable. The aim of this study is to evaluate the midterm results in 12 patients with an Essex-Lopresti injury who were treated operatively.

We studied 12 patients, with comminuted fracture of the radial head, either isolated (4 patients) or with injury of the ipsilateral (4 patients) or the contralateral (4 patients) arm. Initially, 10 patients were treated with excision of the radial head whereas 2 underwent internal fixation of the radial head and pinning of the DRUJ. Eventually, everyone developed a subluxation of DRUJ and had to be treated for an established Essex-Lopresti injury, 1–7 months after the initial injury. Six patients were treated with equalization of the radioulnar length (ulnar shortening osteotomy with or without a distractor-external fixator) and restoration of the TFC, while six patients underwent replacement of the radial head with a titanium implant, equalization of the radioulnar length and restoration of the TFC.

The results were evaluated after a mean follow-up of 4 years (1–12 years), based on radiological and clinical criteria. The six patients in whom the titanium radial head implant was used presented with good results, even though two of them reported forearm pain during activity. On the contrary, in the rest of the patients the radioulnar incongruity reappeared in varying degrees. However the poor radiological result was not consistent to the clinical one.

We conclude that in cases of complete rupture of the interosseous membrane, internal fixation or replacement of the radial head with a metallic implant will not probably provide us with a good long-term functional result.

Correspondence should be addressed to Anastasia C. Tilentzoglou MD, General Secretary of the Board of Directors of HAOST, 20 A. Fleming Str. (N.Filothei), Gr. 15123 Maroussi, Athens Greece. E-mail: info@eexot.gr