S08.2 TREATMENT OF INFECTION IN MEGAPROSTHESES AROUND THE KNEE



Abstract

Endoprosthetic replacement following oncological conditions has shown to be at higher risk of sceptical complications due to the use of implants of unusual size, major soft tissue loss and immunsupression.

373 patients have been treated at our institution for malignant tumours of the bone or soft tissue around the knee with a modular tumour-prostheses of the knee joint since their availability from 1978. Infection or septic complications were identified in 78 patients (20.9%).

In 15 cases of superficial wound healing disturbances with a fistula simple excision and revision of the wound was performed. In 48 cases of deep periprosthetic infections patients underwent one-stage revision with explantation of the total prosthetic material except femoral and tibial stems, extensive debridement of the wound and replantation of the disinfected prostheses throughout one operation. In 8 patients two-stage revision of the prostheses was performed, using an antibiotic impregnated cement spacer and Steinmann nails. In 5 patients amputation of the affected limb was indicated, whereas 2 patients could be treated conservatively. Out of the patients treated by one-stage revision 16 developed recurrent infection and had to undergo consecutive surgery. After two-stage surgery 4 patients showed signs of septic recurrence.

According to our results deep periprosthetic infection of tumour-prostheses primarily can be treated by one-stage revision, in recurrent infections, however, two-stage revision should be performed. We additionally suggest the use of local or pedicled muscle flaps to obtain better soft tissue coverage of the prostheses after infection.

Correspondence should be addressed to Vienna Medical Academy, Alser Strasse 4, A-1090 Vienna, Austria. Phone: +43 1 4051383 0, Fax: +43 1 4078274, Email: ebjis2009@medacad.org