S07.3 SHORT TERM OUTCOME OF A NEWLY DEVELOPED CUSTOMIZED SPACER CONCEPT FOR TREATMENT OF LARGE SEGMENTAL RESECTIONS AFTER PROSTHETIC INFECTION: AN UPDATE OF THE SPACER PROJECT



Abstract

Introduction: Infection is a challenging problem in orthopaedic surgery. In oncologic and revision surgery large prosthesis are placed during long procedures, even in patients with immunocompromised status. Infection rates here are reported up to 10%. Infections may necessitate large segmental resections thereby creating large defects. This defect can be filled with antibiotics loaded beads that release the substances locally to sterilise the defect. In recent years solid antibiotic loaded bone cement spacers have been applied. These spacers fill the defect, stabilize the extremity, release antibiotics and keep the soft tissues on their original length. Additionally, the patients will be able to preserve mobile function as well. In small defects prefabricated bone cement spacers temporarily replace the infected hip or knee prosthesis. For larger segmental of terminal defects there are no readily available constructs.

Purpose: To report short term outcome of a newly developed customized spacer concept for treatment of large segmental resections after prosthetic infection or osteomyelitis.

Material and Methods: We have treated 13 patients with large segmental defects after infection treatment with customized antibiotic bone cement spacers reinforced with strong intra-medullar implants like the Gammanail, the DFN and the UHN.

Results: These customized spacers are easy to make, fill the defect, stabilize the extremity, release antibiotics, keep the length of the soft tissues and allow patients to practice and preserve joint function as well. In 11 of 13 patients operated with an interim construct like this, a successful reimplantation of a tumor prosthesis was performed.

Conclusion: With customized antibiotic bone cement spacers augmented with a solid implant one can fill the defect, stabilize the extremity, release antibiotics and keep the soft tissues on their original length and keep function as well in infected tumorprosthesis. Successful reimplantation could be performed in 11 of 13 cases.

Correspondence should be addressed to Vienna Medical Academy, Alser Strasse 4, A-1090 Vienna, Austria. Phone: +43 1 4051383 0, Fax: +43 1 4078274, Email: ebjis2009@medacad.org