RESULTS OF A NEW REVISION SYSTEM IN COMPLEX HIP AND KNEE REVISION CASES – MEGASYSTEM C BY LINK



Abstract

Introduction: The removal of well-fixed cementless acetabular components can be challenging and may lead to tremendous bone loss. The options for a well-fixed, mal-positioned cup include cup revision, face-changing liners, or eccentrically cementing a liner in a more appropriate position. This study reviews our experience with a technique of eccentrically cemented acetabular liners in wellfixed, malpositioned cementless acetabular components.

Methods: From 2002 to 2004, 30 patients underwent acetabular revisions with eccentrically cemented liners into well-fixed, malpositioned acetabular components. The range of malpositioning included excessive abduction, extreme anteversion, retroversion, and neutral cup position. The cemented liners were downsized by 2–4 mm to provide an acceptable cement mantle and were positioned more appropriately in terms of both abduction angle and anteversion.

Results: Mean follow-up was 4 years (3–5). Liners were reoriented for the following reasons 7 excessive abduction, 8 extreme anteversion, 10 neutral and retroversion, and 5 combined inappropriate version and abduction. One liner loosened at 18 months and required cup revision. The other 29 functioned well with no dislocations. Radiographic analysis demonstrated no loosening in 29 cups at a mean of 4 years (3–5).

Conclusion: Eccentrically cemented liners into well fixed, malpositioned acetabular components in a reasonable option that has promising short-term results.

Correspondence should be addressed to: EFORT Central Office, Technoparkstrasse 1, CH – 8005 Zürich, Switzerland. Email: office@efort.org