header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

NOISE GENERATION IN CERAMIC ON CERAMIC TOTAL HIP JOINT REPLACEMENTS



Abstract

Squeaking in ceramic total hip joint replacements has become a controversial topic. This study aims to document the incidence of squeaking and other noise generation in a single surgeon series for ceramic on ceramic total hip joint replacements. Possible aetiological for squeaking causes are explored.

All patients from public and private who received ceramic on ceramic total hip joint replacements (Stryker trident-accolade) from 2002 to 2007 were identified via the New Zealand Joint registry. Following ethics approval all patients were contacted for a phone interview to question as to whether they had noted any noise generation. Patients who demonstrated noise generation were reviewed in clinic for full history and examination. Data including age, sex, weight, primary diagnosis, head size and cup size were obtained from clinical notes. Post operative x-rays were reviewed to analyse cup abduction and version.

Forty one ceramic total hip joint replacements in a total of thirty seven patients were reviewed via telephone interviews. Three patients complained of squeaking in the ceramic bearing while one patient complained of a grinding and one other of clicking. Two of the three who had recognised the squeaking were both able to reproduce the squeaking in the clinic room. The third patient was noted to have crepitus from anterior patello-femoral osteoarthritis. There was no statistical difference in age, weight, primary diagnosis or head size. In terms of abduction and version of the acetabular cups that squeaked, one had twenty seven degrees of ante-version and forty seven degrees of abduction and the other fifteen degrees of anteversion and thirty degrees of anteversion. Four cups lay outside the recommended fifteen-thirty five degrees of anteversion and thirty five-fifty five degrees of abduction yet showed no squeaking. Neither patient is troubled by the squeaking and neither would seek revision surgery. The incidence of squeaking in ceramic on ceramic total hip joint replacements appears to be around five percent with a similar number of patients experiencing other noises. The position of the acetabular cup does not appear to be the sole contributor to the noise and other aetiological causes need to be further investigated.

Correspondence should be addressed to Associate Professor N. Susan Stott, Orthopaedic Department, Starship Children’s Hospital, Private Bag 92024, Auckland, New Zealand.