TOTAL HIP ARTHROPLASTY IN SCFE – A NOVEL TECHNIQUE TO REMOVE EMBEDDED KNOWLES PIN



Abstract

In situ fixation of mild slips of the slipped capital femoral epiphysis (SCFE) is a safe and reliable method of treatment. Hardware failure and fractures are reported at the time of pin retrieval. Difficulty in removing these pins is well reported. Major problems can be expected when arthroplasty is necessary years later, if the pins are still inside the proximal femur. Hence we have come up with a novel technique to remove these pins during Primary Total hip arthroplasty.

The hip is exposed through posterior approach, dislocated and the neck is then cut at the usual site. It is then segmented in both sagittal and coronal planes into approximately eight to ten pieces and removed piecemeal. The pins are thus exposed, cleared of any bony debris and hammered retrograde.

By using our simple and novel technique to remove these pins we feel it avoids unnecessary trauma to the outer cortex of femur and also reduces the operating time significantly.