UNCEMENTED TOTL HIP ARTHROPLASTY WITH A FEMORAL SHORTENING OSTEOTOMY FOR CROWE TYPE 3 OR 4 DEVELOPMENTAL DYSPLASIA OF THE HIPS WITH THE USE OF THE MODULAR S-ROM PROSTHESIS



Abstract

Treating Crowe type 3 or 4 of hips tends to be technically difficult when performing total hip arthroplasty (THA) due to the severely dysplastic acetabulum and proximal femur in addition to a high dislocation of the hip. Since the socket is limited to being placed at the original hip center, a femoral shortening osteotomy is often required in order to prevent neurovascular problems. This osteotomy will need the stability of the femoral stem with both the proximal and the distal femoral bones. We used the modular S-ROM stem, which has a valuable proximal structure and a distal flute structure to stabilize the stem with the proximal and distal femoral fragments. The purpose of this study was to report the clinical and radiographic results of the primary THA with a shortening osteotomy while also using the S-ROM prosthesis.

Between 1994 and 2004, primary THA using the S-ROM prosthesis was performed on 7 hips in 6 cases (1 male, 5 females). Crowe type 3 or 4 was observed in one and 6 hips, respectively. The mean age at operation was 56 years old (range 51~60). The mean follow-up period was 41 months (range 24~56 months). Four hips had previously undergone a subtrochanteric valgus osteotomy. All hips underwent a step-cut femoral osteotomy at the proximal metaphysis for the shortening and/or correction of angulations with on-lay chip bone grafts. All of the used stems were straight type. The clinical outcome was evaluated using the clinical scoring system of hip joints established by the Japanese Orthopaedic Association (JOA). According to a 100 point scale, pain was determined to be 40, ROM was 20, gait was 20 and ADL was 20.

No hips had undergone any revision surgery as of the most recent follow-up. Union was achieved at the osteotomy site in all hips. Neither osteolysis nor a loosening of the implant was radiographically observed. The mean JOA score before THA and at the last follow-up was 41 (31–48) and 81 (62–91) points, respectively. The mean postoperative days to start full weight bearing was 53 days (range 49~70). In two cases (28%), a procedure using circular wiring was performed to treat a crack in the proximal femur.

The S-ROM prosthesis was thus found to be useful for primary THA with a shortening metaphyseal femoral osteotomy for hips in patients with Crowe type 3 or 4 developmental dysplasia.

Correspondence should be addressed to ISTA Secretariat, PO Box 6564, Auburn, CA 95604, USA. Tel: 1-916-454-9884, Fax: 1-916-454-9882, Email: ista@pacbell.net