Full Access

A COORDINATE SYSTEM FOR THREE DIMENSIONAL DATA ANALYSES IN THE FOOT AND ANKLE.



Abstract

Complex foot and ankle surgery and reconstruction require accurate preoperative planning. In the foot procedures are challenging and can be associated with a range of complications. The aim of planning is to correct only the deformity and prevent extensive surgery. Knowledge of foot and ankle morphometry is vital. For comparison between different subjects the coordinate system must be constant. To the authors knowledge there has been no previous description of a coordinate system for the foot and ankle.

CT images of ten anatomically normal feet were segmented in a general purpose segmentation program for grey value images and imported to a shape analysis program for biomechanics. A coordinate frame was defined in a 3 × 3 identity matrix using the inter-malleolar axis and a fibular diaphyseal centroidal axis in the construction. Centroidal vectors were defined in the metatarsals. Correlation of metatarsal length, inter-metatarsal angles, inter-malleolar distance and height was carried out.

The forefoot was examined in relation to the medial and lateral columns. Metatarsal length had a significant correlation within each column and between the two columns notably in the 3rd (0.525 – 0.965) metatarsal at the columns junction. The 3rd metatarsals also correlated significantly (−0.583) with the inter-metatarsal angles. There was a weak correlation between the 1st 3rd and the 3rd 5th inter-metatarsal angles directly however, each had a large correlation with the 1st 5th inter-metatarsal angle (0.734 – 0.950). There was also a large correlation between the individual’s stature and the metatarsal length and the inter-malleolar distance.

We have presented a means defining a coordinate system for three dimensional analyses in the foot and ankle. This coordinate system can be used for meaningful comparison of data between multiple subjects. We have shown that this coordinate system to be effective in practice in the morphometrical analysis of the normal forefoot.

Correspondence should be addressed to EORS Secretariat Mag. Gerlinde M. Jahn, c/o Vienna Medical Academy, Alserstrasse 4, 1090 Vienna, Austria. Fax: +43-1-4078274. Email: eors@medacad.org