DYNAMIIC NEUTRALIZATION SYSTEM COMPLICATED BY ACCLERATED ADJACENT SEGMENT DEGENERATION



Abstract

Introduction: We report a series of 10 cases from a cohort of 421 Dynesys procedures in which evidence of Accelerated Adjacent Disc Disease (AASDD).

Spinal fusion for degenerative disc disease is known to have inconsistent outcomes. One concern is the possibility of AASDD as a result of the altered kinematics. The Dynamic Neutralisation System (Dynesys) appears to offer an advantage in that it restricts, rather than abolishes movement at the treated segment, and should thereby reduce the problem of AASDD, In the event of failure, it can in addition be removed, returning the spine to the former status quo. Various biomechanical studies confirmed flexibility of Dynesys.

Method: Ten patients developed new and symptomatic disc disease within segments adjacent to Dynesys. The average age of patients was 49 year with range between 36–70 years. Average post Dynesys to secondary surgery for ASD was 24.7 months. Previous discography and MRI in all cases had shown no evidence of disc disease within these adjacent segements prior to Dynesys. All patients were evaluated preoperatively using Oswestry Disability Index, SF 36 and Visual Analogue Scores together with plain x ray imaging, MRI scanning and discography. Of this cohort Dynesys was indicated to treat single disc level in 7 and two levels in 3

Results: Incidence of AASDD associated with Dynesys was 2.1%. Further surgical intervention included:

  • Extension of Dynesys10

  • Dynesys combined with MIF2

  • Dynesys combined with PLIF2

There was no caudal ASD in our cohort.

Discussion & Conclusions: Dyensys did not prevent the development of accelerated ASD. Evidence from Aylott cadaver studies suggests that Dynesys instrumentation alters the Kinematics of the adjacent segment and increases the excursion. It is unclear whether the small number of AASDD reported here is other than the natural progression of degenerative change. 95.7 cases did not progress.

Correspondence should be addressed to EORS Secretariat Mag. Gerlinde M. Jahn, c/o Vienna Medical Academy, Alserstrasse 4, 1090 Vienna, Austria. Fax: +43-1-4078274. Email: eors@medacad.org