Full Access

NEW KINEMATIC EVALUATION OF TKA OUTCOME BY MEANS OF A NAVIGATION SYSTEM



Abstract

Total knee arthroplasty (TKA) is actually a satisfactory technique to reduce pain and enhance mobility in osteoartritic pathologies (OA) of the knee. However, life of the implant is strictly dependent on restoration of correct knee kinematics, as alteration of motion pattern could led to abnormal wear in prosthetic components and also damage soft tissues. The aim of our study was to evaluate new kinematic tests to be performed during surgery in order to improve the standard intra-operative evaluation of the outcome on the individual case. We used Kin-Nav navigation system to acquire anatomic and kinematic data, which were analysed by a dedicated elaboration software developed at our laboratory. Ten patients undergoing rotating platform cruciate substituting TKA were considered for this study. Immediately before the implant and immediately after component positioning, the surgeon performed 3 complete knee flexion imposing internal tibial rotation (IPROM) and 3 complete knee flexion imposing external tibial rotation (EPROM). Tibial rotation during IPROM and EPROM tests was plotted in function of flexion (in the range 10°–110°). Repeatability of IPROM and EPROM was tested by calculating ICC (Intra-class Correlation Coefficient) between 3 repeated curves. Distance between IPROM curve and EPROM curve was computed at various degree of flexion. Maximum distance obtained during all range of flexion before and after the implant were compared by Student’s t-test (significant level p=0.05).

ICC for repeated motions were 0.99 for IPROM and 0.98 for EPROM. Maximum distance between tibial rotation in IPROM and EPROM was 27.82±6.98 before implant and significantly increased (p=0.001) to 40.09±6.92 after TKA. In one case we observed that the value remained similar before and after implant (from 33.11 to 33.98) while in one case we observed very large increase of rotation (from 30.56 to 50.01).

The proposed kinematic tests were able to quantify the increase of tibial rotation after TKA implant. Future development of the study are encouraging and will include a larger sample and reflections on individual findings.

Correspondence should be addressed to Mr K Deep, General Secretary CAOS UK, Dept of Orthopaedics, Golden Jubilee National Hospital, Glasgow G81 4HX, Scotland. Email: caosuk@gmail.com