MEASURING THE POSITION OF THE ACL FOOTPRINT WITH A NAVIGATION SYSTEM. COMPARISON WITH X-RAY AND CT MEASUREMENTS.



Abstract

Anterior cruciate ligament (ACL) reconstruction allows overall good results, but there is still a significant rate of failure. It is well accepted that the main reason for ACL reconstruction failure is a misplacement of tibial or femoral tunnels. Conventional techniques rely mainly on surgical skill for intra-operative tunnel placement. It has been demonstrated that, even by experienced surgeons, there was a significant variation in the accuracy of tunnel placement with conventional techniques. Navigation systems might enhance the accuracy of ACL replacement.

10 cadaver knees with intact soft-tissue and without any intra-articular abnormalities were studied. We used a non image based navigation system (OrthoPilot ®, Aesculap, Tuttlingen, FRG). Localizers were fixed on bicortical screws on the distal femur and on the proximal tibia. Both kinematic and anatomic registration of the knee joint were performed by moving the knee joint in flexion-extension and palpating relevant intra- and extra-articular landmarks with a navigated stylus. The most anterior, posterior, medial and lateral point of both tibial and femoral attachment of the ACL were marked with metallic pins. The navigated stylus was positioned on these points, and the system recorded its position in comparison to the bone contours. Subsequently, we performed conventional plain AP and lateral X-rays and a CT-scan, and measured the position of the pins in comparison to the bone contours. Finally, all measurements were made again with a caliper after disarticulating the knee joint. We calculated the center of the footprint as the mid-point between the four pins of both tibial and femoral attachment for each measurement technique. All measurements were expressed as percentages of the bone size to compensate for the different sizes.

There were no significant difference in the paired measurements of the location of the ACL footprints on both femur and tibia between anatomic, radiographic, CT-scan and navigated measurements. There was a significant correlation between the paired measurements of the location of the ACL footprints on both femur and tibia with either measurement techniques.

Anatomic measurement is the gold standard experimental technique for the positioning of the ACL foot-print, and CT-scan measurement is currently the gold standard technique in clinical situation. According to this reference, the position of ACL attachments on the tibia and on the femur can be accurately defined by the navigation system. Intra-operative measurement of the location of the bone tunnels during ACL replacement with this navigation system should be accurate as well.

Correspondence should be addressed to Mr K Deep, General Secretary CAOS UK, Dept of Orthopaedics, Golden Jubilee National Hospital, Glasgow G81 4HX, Scotland. Email: caosuk@gmail.com