header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

TWO-STAGE REIMPLANTATION WITH APPLICATIONSPACER FOR ANTIBIOTICS IN SEPTIC TOTAL ARTHROPLASTY



Abstract

Acute periprosthetic infection, acute and chronic course of the infection with unknown spectrum of organism, hardly to treat and loss of mobility due to long lasting immobilization after implant removal are the indications for this special design of a spacer. The management of a bacterial periprosthetic infection by two-stage reimplantation using an implanted applicationspacer for antibiotics maintains mobility and soft tissue balance and ensures simultaneous local delivery of antibiotics.

After a complete synovectomy the implant components and all foreign material are removed. The implant bed is then prepared for implantation of the application-spacer for antibiotics. Silicone catheters are advanced through two separate drill holes into the intramedullary canal and then inserted into the perforated implant stems. After the applicationspacer for antibioticss has been implanted, the wound is closed.

Daily parenteral doses of antibiotics are delivered through the percutaneous silicone catheters directly into the intramedullary canal at the site of the infection. The applicationspacer for antibiotics allows daily physiotherapy and even mobilization on a CPM device. Partial weight bearing may even be allowed if there is sufficient stability. Once the CRP values have decreased to normal levels, the definitive implant is placed using antibiotic-impregnated cement according to current resistance studies. The implant beds are debrided to remove the synovial tissue that has developed in the interim. Then the revision implants can be placed in the prepared bone because the same templates are used for both the applicationspacer for antibioticss and the revision implants.

36 patients have been treated with this method since 1993. Two-stage reimplantation of a total knee was performed in 27 cases.. The longest postoperative follow-up period is now 12 years. Till now, no revision surgery has been required on a joint treated in this manner, and no periprosthetic infections have been observed. In the knee, a range of motion of 0/0/106 degrees was achieved after an average follow-up period of 7,1 years. In the hip, values of 10/0/110 degrees were achieved after an average of 7,3 years. Revision surgery for infection included cases of fungal and tubercular infection. A postoperative Hospital for Special Surgery rating of 79,5 was achieved in the knee and a rating of 81,3 in the Harris hip score.

Correspondence should be addressed to Ms Larissa Welti, Scientific Secretary, EFORT Central Office, Technoparkstrasse 1, CH-8005 Zürich, Switzerland