header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

RELEASE OF COBALT AND CHROMIUM IONS INTO THE SERUM FOLLOWING IMPLANTATION OF THE METAL-ON-METAL MAVERICKTM TYPE ARTIFICIAL LUMBAR DISC (MEDTRONIC SOFAMOR DANEK)



Abstract

Study design: Cross-sectional study of 10 patients to measure the serum levels of cobalt and chromium after TDA.

Summary of Background Data: In total hip endoprosthetics and consequently for TDA (total disc arthroplasty), metal-on-metal combinations are used with the aim of reducing wear debris. In metal-on-metal TDA the release of metal ions has until now been secondary to the main discussion.

Objectives: To investigate the release of cobalt and chromium ions into the serum following implantation of the metal-on-metal MaverickTM type artificial lumbar disc.

Materials and methods: We investigated the serum cobalt and chromium concentration following implantation of 15 Maverick™ TDAs (monosegmental L5/S1 n=5; bisegmental L4/5 and L5/S1 n=5; average age = 36.5 years). 5 healthy subjects (no metal implants) acted as a control group. The measurements of the metals were carried out using the HITACHI Z-8200 AAS polarized Zeeman atomic absorption spectrometer after an average of 14,8months.

Results: The concentrations of cobalt and chromium ions in the serum amounted on average to 4.75μg/l (standard deviation 2,71) for cobalt and 1.10μg/l (standard deviation 1,24) for chromium. Compared to the control group, both the chromium and cobalt levels in the serum showed significant increases (Mann-Whitney Rank Sum Test, p=0.0120). At follow-up the Oswestry Disability Score was on average significantly decreased by 24.4 points (L5/S1) (t-test, p < 0.05) and by 26.8 points (L4-S1)(t-test, p < 0.05). The improved clinical situation is also represented by a significant decrease of the Visual Analog Pain Scale of 42,2points after the follow-up (t-test, p< 0,05).

Conclusion: Significant systemic release of Cr/Co was proven in the serum compared to the control group. The concentrations of Cr/Co measured in the serum are similar in terms of their level to the values measured in THA metal-on-metal combinations or exceed these values given in the literature. Long-term implication of this metal exposuere in unknown and should be studied further.

Correspondence should be addressed to Ms Larissa Welti, Scientific Secretary, EFORT Central Office, Technoparkstrasse 1, CH-8005 Zürich, Switzerland