header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

A NEW MINIMAL INVASIVE APPROACH FOR THE BERNESE PERIACETABULAR OSTEOTOMY. TECHNIQUE, RESULTS AND COMPARISON TO THE ILIOINGUINAL APPROACH.



Abstract

Introduction: Minimal invasive surgery (MIS) seems to be part of future orthopaedic solutions. Currently, most approaches for the Bernese periacetabular osteotomy (PAO) are characterized by relatively extensive incisions, dissection and detachment of muscles. We have developed a new MIS approach for the Bernese PAO. The purposes were to reduce patient morbidity and to improve the cosmetic result following surgery without negatively influencing the achieved reorientation of the acetabular articular surface. In this study we present the surgical technique, results and compare them to the ilioinguinal (II) approach.

Methods: The new MIS technique is a trans-sartorial approach using a three inch skin incision. Previously the II approach was used. From 1999–2006 a total of 215 patients with acetabular dysplasia were operated by the same surgeon in two successive time periods with the II (97) and the trans-sartorial (118) approaches. No supplemental surgery was performed. The two approaches are retrospectively compared regarding perioperative measures, transfusion requirements, complications and the achieved reorientation of the acetabular articular surface. Data are compared by Kruskal-Wallis Test and are presented as median and interquartile range.

Results: The trans-sartorial approach significantly reduced days of admission (8 days (7–9) vs. 10 days (8–13), p< 0.0001), duration of surgery (70 min (60–75) vs. 100 min (82.5–120), p< 0.0001), perioperative blood loss (200ml (150–350) vs. 450ml (325–700), p< 0.0001) and the percentage of patients receiving blood transfusion (18.6 % vs. 3.4%). Of severe neurovascular, infectious and technical complications none occurred in the trans-sartorial group and 3 cases of arterial thrombosis were seen in the II group. The achieved reorientation measured by the CE-angle postoperatively had median values of 31° (25–36) in the II group and 33° (29–36) in the trans-sartorial group, p=0.016. The postoperative AI-angles were 10° (2–14) and 3° (0–7) in the II and trans-sartorial groups respectively, p< 0.0001.

Discussion: Our shift to the trans-sartorial approach was rewarding as the duration of surgery, perioperative blood loss and transfusion requirements were reduced. The new MIS technique is safe and improves the cosmetic result without negative influence on the achieved reorientation of the acetabular articular surface.

Correspondence should be addressed to Ms Larissa Welti, Scientific Secretary, EFORT Central Office, Technoparkstrasse 1, CH-8005 Zürich, Switzerland