header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

COST-EFFECTIVENESS OF TWO FORMS OF CIRCUMFERENTIAL LUMBAR FUSION: A PROSPECTIVE, RANDOMISED, CONTROLLED TRIAL



Abstract

Study Design: Economic evaluation alongside a prospective, randomized, controlled trial from a 2-year NHS perspective.

Objective: To determine the cost-effectiveness of Titanium Cages (TC) compared to Femoral Ring Allografts (FRA) in circumferential lumbar fusion.

Summary of background data: A randomised controlled trial has shown the use of TC to be clinically inferior to the established practice of using FRA in circumferential lumbar fusion. Health economic evaluation is urgently needed to justify the continued use of TC, given that this treatment is less effective and, all things being equal, more costly than FRA.

Methods: Eighty-three patients were randomly allocated to receive either the TC or FRA as part of a circumferential lumbar fusion between 1998 and 2002. NHS costs related to the surgery and revision surgery needed during the trial period were monitored and adjusted to the base year (2005/6 pounds sterling). The Short Form-6D (SF- 6D) was administered preoperatively and at 6, 12 and 24 months in order to elicit patient utility and subsequently Quality-Adjusted Life Years (QALYs). Return to paid employment was also monitored. Bootstrapped mean differences in discounted costs and benefits were generated in order to explore cost-effectiveness.

Results: A significant cost difference of £1,942 (95% CI £849 to £3,145) in favour of FRA was found. Mean QALYs per patient over the 24 month trial period were 0.0522 (SD 0.0326) in the TC group and 0.1914 (SD 0.0398) in the FRA group, producing a significant difference of 0.1392 (95% CI 0.2349 to 0.0436). With regard to employment, incremental productivity costs were estimated at £185,171 in favour of FRA.

Conclusion: From an NHS perspective, the trial data show that TC is not cost-effective in circumferential lumbar fusion. The use of FRA was both cheaper and generated greater QALY gains. FRA patients reported a greater return to work rate.

Correspondence should be addressed to: Mr N. J. Henderson, BASS, c/o BOA, The Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London WC2A 3PE.