ANTERIOR LUMBAR INTERBODY CAGES IN SCOLIOSIS SURGERY-ROLE OF INTRAOPERATIVE SCREENING.



Abstract

Anterior Lumbar Interbody Cages are used to recreate the lumbar lordosis in scoliosis surgery as anterior instrumentation is usually kyphogenic. We report two cases in which an anterior release was performed and interbody cages were used.In both these patients the cage was displaced anteriorly by an incorrectly positioned pedicle screw during posterior instrumentaion. In one case the cage was retrieved and correctly repositioned from the back using a TLIF approach, in the other this was noticed only post-operatively and patient needed another anterior surgery. We recommend a lateral Image Intensifier screening for combined anterior and posterior cases in which anterior cages are used in addition to posterior pedicle screws to prevent this complication.

Correspondence should be addressed to: Dr Caroline Goldberg, The Research Centre, Our Lady’s Children’s Hospital Crumlin, Dublin 12, Ireland.