CLOSED TIBIAL FRACTURES TREATED BY MONOLATERAL EXTERNAL FIXATION.



Abstract

A prospective study of 196 closed tibial diaphyseal fractures treated by a monolateral external fixator is presented.

The patients were managed by a group of Surgeons including the senior author (PBMT), a definitive fixator being used in 34 patients, and a fracture reduction device in 162 patients. All the patients were followed up in an external fixator clinic by the senior author, and follow up continued for 1 year after the fractures had healed. Fracture healing was determined clinically.

There were 196 tibial fractures, with an average age of 29 years (range 12–80 years). 111 Fractures involved the right tibia, and 85 the left. There were 166 males and 30 females. 116 Fractures were deemed due to a low energy accident, and 80 due to a high energy injury. The most common mechanism of injury was football (75), a fall (52), a road vehicle accident (49), direct trauma (7), assault (4), and rugby (3). According to the AO classification system 33 were A1 fractures, 47 A2, 42 A3, 15 B1, 46 B2, and 7 B3. Time to fracture healing was 19 weeks on average (with a range from 9–87 weeks).

15 Fractures united with a deformity of more than 50 in the coronal plane. One patient required a corrective osteotomy for a mal-united fracture. There were 279 pin track infections that required antibiotic treatment in 85 patients. 33 Pins had to be removed due to persistent infection. Of these patients 15 developed 32 ring sequestrae, but infection was settled by debridement under GA. 7 External fixators had to be removed early because of pin site infection. One patient developed a full blown osteomyelitis, which was treated with the Lautenbach irrigation and settled. There were 7 re-fractures, but all healed after further treatment. 5 Were treated in a POP cast and 2 were re-treated with another external fixator. There were 7 non-unions, but all eventually healed with further treatment with an external fixator.

The authors conclude that treating a closed tibial fracture with an external fixator is a viable alternative method of treatment.