Full Access

DO ANTERIOR INTERBODY CAGES HAVE A POTENTIAL VALUE COMPARED TO AUTOLOGOUS RIBGRAFT IN THE SURGICAL MANAGEMENT OF SCHEUERMANN’S KYPHOSIS?



Abstract

Purpose: To investigate the potential value of titanium anterior interbody cages compared to morselized rib graft for anterior interbody fusion in combination with posterior instrumentation, correction and fusion for Scheuermann’s kyphosis.

Methods and Materials: A Non-Randomised historic cohort study of two surgical techniques in matched subjects was carried out.15 patients with identical pre-operative radiographic and physical variables (age, gender, height, weight, BMI ) were managed with combined anterior release, interbody fusion, posterior instrumentation, correction and fusion . Group A (n=8) had morsilized rib graft inserted into each intervertebral disc space. Group B (n=7) had titanium interbody cages packed with bone graft inserted at each level. The posterior instrumentation extended from T2 to L2 in both groups. Pre- and post-operative curve morphometry was studied on plain radiographs by two independent observers. The indices studied included Cobb angle, Ferguson’s angle(FA) , Voutsinas index(VI), Sagittal Vertical Axis (SVA), Sacral Inclination (SI) and Lumbar Lordosis (LL). Interbody Fusion was assessed at final follow up. Each patient was reviewed at 3, 6, 12, 24, 48 and 60 months following surgery with standing radiographs. Wilcoxon-matched pairs test and Mann-Whit-ney test were used for statistical analysis.

Results: The average follow-up for groups A was 70 and Group B,66 months. For the whole group, the pre-operative : postoperative median Cobb angle, FA, VI, SVA and SI were 86: 42degrees, 50 : 28.4degrees, 28.7 :13, −3.5 : −4.0 centimetres and 40 : 34 degrees respectively. There were significant differences for all variables [p< 0.01] indicating good correction. At four-year follow-up, fusion criteria were satisfied in 12 / 15 cases (80%). Three patients had distal junctional kyphosis. There was no significant difference with respect to the variables between the two groups and both retained the post-operative correction achieved.

Conclusion: There was no significant advantage in the use of anterior titanium interbody cages over the use of morselized rib graft in the surgical management of Scheuermann’s Kyphosis.

Correspondence should be addressed to: Sue Woodward, Secreteriat, Britspine, Vale Clinic, Hensol Park, Vale of Glamorgan, CF72 8JY Wales.