CONCAVE THORACOPLASTY (CTP) AND POSTERIOR INSTRUMENTATION FOR CORRECTION OF RIGID THORACIC SCOLIOSIS: RESULTS AT FIVE TO SEVEN YEARS



Abstract

Introduction: In rigid AIS, the main resistance for thoracic derotation are the anteriorly rotated ribs on the concavity. This study presents clinical and radiographic long term results of the CTP, which is a routine surgical procedure at the authors’ institution.

Material and Methods: Between 1996 and 1997 we have operated on 466 cases of scoliosis. 36 patients with thoracic AIS were evaluated. Technique: The ribs on the concave side are osteotomised close to the costo-transverse joint and elevated over the bended rod.

Results: Mean follow up was 6.4 y. Mean preoperative side bending flexibility was 21%. Mean correction rate was 68%, mean rib hump correction was 3cm. Mean loss of correction 4°. There was no neurological complication, and pulmonary morbidity was not increased.

Conclusion: In rigid thoracic scoliosis, a release of the concave ribs by means of the CTP can both significantly increase the extent of correction and contributes to an excellent cosmetic result.

Correspondence should be addressed to Jeremy C T Fairbank at The Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford OX7 7LD, UK