header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

P83 POSITION OF CIRCUMFERENTIAL SUTURE AND CORE SUTURE KNOTS IN TENDON REPAIR AND ITS INFLUENCE ON GAPPING AND FAILURE ENERGY



Abstract

Purpose: To find if there is any difference in gapping of tendon repair on cylcic loading and energy to failure of tendon repair when the circumferential suture knot is placed on the same side of the core suture knot or to the opposite side of the core suture knot.

Methods: Ten pig flexor tendons were repaired using 3 0 braided Polyester (Ethibond) as core suture (modified Kessler) and 6 0 Nylon as circumferential stitch (Hal-stead). Five tendons were repaired with the circumferential suture knot placed on the same side as the core suture (Group I) and the other five placed on the opposite side (Group II). Allocation to either of the groups was random. Using a testing machine the tendons were cyclically loaded and the energy to failure was calculated. Gapping during cylical loading was recorded using digital images.

Results: Mean gapping in Group I was 0.01 mm and in Group II was 0.03mm. This was not statistically signifi-cant (2x3 ANOVA, p > 0.3). The mean load to failure in group I was 58.7 N (55 to 65) and in group II was 59.5 N (54 to 67). This was also not statistically significant (p > 0.3 one way ANOVA).

Conclusion: There is no difference in gapping and energy to failure of tendon repair when the circumferential suture knot is placed on the same side of the core suture knot or to the opposite side of the core suture knot.

Correspondence should be addressed to Mr Carlos Wigderowitz, Senior Lecturer, University Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, Dundee DD1 9SY.