OP5 A NOVEL APPROACH TO CREATING A BIO MIMETIC HYDROXYAPATITE COATING ON FINE SURFACE FEATURES TO ENHANCE OSSEOINTEGRATION OF EXTERNAL FIXATION SCREWS



Abstract

Background: As the understanding of bone repair mechanics has advanced the integrity of the bone pin interface has emerged as a key factor in determining the success of external fracture fixation. The benefits of using pins coated with Hydroxyapatite (HA) are well documented however the thickness of the conventional plasma spray coating precludes its use for modification of the surface of fine features in implants. Consequently new electro-chemical techniques for pre-coating implants with a ‘biomimetic’ HA layer using simulated body fluids (SBF) have been pioneered. In this study we test the hypothesis that varying the technique for deposition of HA by electrolysis of SBF alters the morphology of the HA surface which will modify the level of osseointegration. Method: Three alternative methods of HA coating the Barerre, Redepenning and Kumar techniques were compared. Tantalum coated stainless steel pins were coated then used to stabilise a mid-diaphyseal osteotomy in three sheep using an orthofix fixator for a period of ten weeks. Insertion and extraction torques were measured to calculate the pin performance index (PPI). Sections of the bones were then examined using scanning electron microscopy to determine the percentage of bone in contact with the pin surface and the percentage of new bone formation. Results: The different coating protocols resulted in different HA crystal morphologies. The extraction torque exceeded the insertion torque for both the Barerre and Redepenning methods and their PPI exceeds that of plasma spray coatings. The Redepenning technique was shown to perform sig-nificantly better than both the Barerre (p=0,001) and Kumar (p=0,001) techniques with 49.4% of the pin surface in contact with bone. These results were mirrored on analysis of new bone formation with the Redepen-ning technique showing 70.2% of new bone formation compared to the Barerre (55.4%) and Kumar (53.8%) methods. Conclusion: These results indicate that the Redepenning technique is the most effective for creating a bio mimetic HA coating in terms of bonding to bone and promoting new bone formation. This technique holds significant advantages over the conventional plasma spray technique for example the coating thickness can be easily controlled and additional proteins such as bone morphogenic proteins and antibiotics can be incorporated. It may therefore represent a new era in the use of HA coating.

Correspondence should be addressed to Mr Carlos Wigderowitz, Senior Lecturer, University Department of Orthopaedic and Trauma Surgery, Ninewells Hospital and Medical School, Dundee DD1 9SY.