WHAT ARE THE IMMUNOLOGICAL EFFECTS OF METAL IONS FROM HIP RESURFACING?



Abstract

Introduction: There have been 70,000 hip resurfacings implanted, predictions are for it to become 12% of the US hip replacement market by 2010 (Goldmann Sachs report Oct 2005). There is concern that the cobalt and chromium ions released from metal on polyethylene hip replacements cause immune dysfunction in the form of T cell mediated hypersensitivity (indicated by increased numbers and stimulation of T cells). If metal ions cause significant effects on white blood cells we might reasonably expect to detect this by simply measuring numbers of white blood cells.

Aim : To examine the possibility that raised metal ions may cause an abnormal number of white blood cells, termed a blood dyscrasia.

Method : Peripheral blood samples were analysed from 68 patients: 34 in the hip resurfacing group and 34 in the standard hip arthroplasty group. Samples were analysed for counts of each sub-group of lymphocyte. Functional assessment was also performed using a activation panel of white cell CD markers. Whole blood cobalt and chromium ion levels were measured using inductively-coupled mass spectrometry. All hip components were well fixed.

Results : Cobalt and chromium levels were significantly elevated in the resurfacing group compared to the hybrid group (p< 0.001). There was a statistically significant decrease in the resurfacing groups’ level of CD8+ cells (T cytotoxic/suppressor) (p=0.010). There was a characteristic pattern of immune modulation seen on the activation panel.

Conclusions : We found an immune modulation in patients with metal on metal hip resurfacing. This was not a hypersensitivity reaction. This change in T cell function may be detrimental or beneficial to patients.

Correspondence should be addressed to The Secretary, BHS, c/o BOA, The Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London WC2A 3PE.