header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

ELECTROCHEMICAL METHOD FOR REAL-TIME MEASUREMENT OF CHANGES IN HYDRATION OF THE INTERVERTEBRAL DISC



Abstract

Background and Purpose: During normal loading of the spine, the intervertebral disc (IVD) experiences large changes in hydration. Current techniques to determine IVD hydration in vitro non-destructively are costly (e.g. MRI). Here we determined the variation in hydration in loaded IVDs electrochemically using needle microelectrodes.

Methods: The relation between hydration and electrochemical current measured in the tissue at a polarising voltage of −0.65V was established in bovine caudal disc nucleus slices. Bovine caudal IVDs were then placed in a culture chamber and tissue hydration varied by applying static loads. Silver needle microelectrodes were inserted into the nucleus at defined locations and the polarising voltage applied. The electrochemical current was measured and hence hydration of the disc determined in relation to duration and magnitude of the applied load.

Results: Intradiscal current was found to correlate directly with tissue hydration, falling 45% as hydration decreased from 0.8 to 0.6. Changes in tissue hydration in response to static load were monitored at different positions in the disc in real-time by measuring electrochemical current and were found to vary spatially and in time as predicted from theory.

Conclusions: Electrochemical measurements can be used as a non-destructive and relatively inexpensive method for real-time measurements of changes in IVD hydration in response to mechanical loading in vitro.

Correspondence should be addressed to Ms Alison McGregor, c/o BOA, SBPR at the Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London WC2A 3PE.