DOES THE CRUCIATE MECHANISM FAIL IN THE LONG TERM AFTER FIXED BEARING MEDIAL UNICOMPARTMENTAL ARTHROPLASTY?



Abstract

Medial unicompartmental replacement (UKR) has been shown to have superior functional results to total knee replacement (TKR) in appropriately selected patients, and this has been associated with a resurgence of interest in the procedure. This may relate to evidence showing that the kinematic profile of UKR is similar to the normal knee, in comparison to TKR, which has abnormal kinematics. Concerns remain over the survivorship of UKR and work has suggested the anterior cruciate ligament (ACL) may become dysfunctional over time. Cruciate mechanism dysfunction would produce poor kinematics and instability providing a potential mechanism of failure for the UKR.

Aim: To test the hypothesis that the sagittal plane kinematics (and cruciate mechanism) of a fixed bearing medial UKR deteriorate over time (short to long term).

A cross sectional study was designed in which 24 patients who had undergone successful UKR were recruited and divided into early (2–5 years) and late (> 9 years) groups according to time since surgery. Patients performed flexion/extension against gravity, and a step up. Video fluoroscopy of these activities was used to obtain the Patellar Tendon Angle (PTA), the angle between the long axis of the tibia and the patella tendon, as a function of knee flexion. This is a previously validated method of assessing sagittal plane kinematics of a knee joint.

This work suggests the sagittal plane kinematics of a fixed bearing UKR is maintained in the long term. There is no evidence that the cruciate mechanism has failed at ten years. However, increased tibial bearing conformity from ‘dishing’, and adequate muscle control, cannot be ruled out as possible mechanisms for the satisfactory kinematics observed in the long term for this UKA.