MECHANICAL PROPERTIES OF CANCELLOUS BONE OF THE DISTAL HUMERUS



Abstract

Three 3mm transverse slices were sectioned from the distal cancellous region of seven fresh-frozen cadaveric humerii. Each slice was marked with a 3x3mm grid, and subjected to compressive testing using a flat cylindrical indenter (1.6mm diameter). Indentation modulus and strength were calculated for each site, and pooled into nine anatomically-defined regions. The most distal slice had higher moduli values (p< 0.05), and the posterior capitellar region had lower moduli values (p< 0.05). There were no slice or regional differences in strength. This suggests that surgical procedures requiring cancellous fixation utilize the most distal aspect of the humerus while avoiding the posterior capitellum.

To quantify the indentation strength and modulus of distal humeral cancellous bone, and identify any regional variations.

Cancellous bone modulus in the distal humerus decreases from distal to proximal. The posterior capitellum has a lower modulus than the other regions of the distal humerus.

The influence of slice depth emphasizes the importance of minimizing the amount of bone removed during prosthetic replacement. Regional variations in modulus suggest that the posterior capitellum should be avoided during fixation of implants or placement of screws.

Three 3mm transverse cancellous bone slices obtained from the distal end of each of seven fresh-frozen cadaveric specimens were subjected to compressive testing using a materials testing machine with a 1.6mm flat cylindrical indenter. Testing was performed in a 3x3mm grid. The indentation modulus and local strength were calculated for each test site, and then averaged into nine regions defined by the capitellum, medial and lateral trochlea, and anterior, central and posterior sections for each slice. Mean modulus was found to be 309.8±242.0 MPa (range: 2.9–1041.7 MPa). Yield strength averaged 4.4±2.5 MPa (range: 0.6–16.3 MPa). The highest modulus was found in the distal-most slice (p< 0.05). The lowest modulus region was the posterior capitellum (p< 0.05). There were no differences in strength between slices or across the nine regions. A comparison with proximal tibial cancellous bone properties suggests the distal humerus may carry loads approaching 30% of those at the knee, assuming that bone adapts to stress magnitudes.