header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

FUNCTIONAL AND ONCOLOGIC OUTCOME AFTER COMBINED ALLOGRAFT AND TOTAL HIP ARTHROPLASTY RECONSTRUCTION OF LARGE BONY PELVIC DEFECTS FOLLOWING TUMOUR RESECTION.



Abstract

A retrospective review of our prospectively collected database was undertaken to determine the functional and oncologic outcome following combined pelvic allograft and total hip arthroplasty (THA) reconstruction of large pelvic bone defects following tumour resection. There were twenty-four patients with a minimum followup of fifteen months. The complication rate following hemipel-vic allograft and THA reconstruction of resection Types I+II and I+II+III was high, but when successful this reconstruction resulted in reasonable functional outcome. In comparison, the functional outcome after allograft and THA reconstruction of isolated Type II acetabular resections was better and more predictable.

Resection of large pelvic bone tumours often results in segmental defects with pelvic discontinuity and loss of the acetabulum. We reviewed the functional and oncologic outcomes following pelvic allograft and total hip arthroplasty (THA) reconstruction.

Reconstruction of large pelvic defects including the acetabulum using hemipelvic allograft and THA is associated with high complication rates, however when successful provides reasonable function. In comparison, the outcomes of allograft and THA for acetabular defects alone are better and more predictable.

A retrospective review of our prospectively collected database was undertaken. Minimum followup was fifteen months (15–167). Nineteen patients were hemipel-vic resections (twelve Type I+II and seven Type I+II+III, eleven cases including partial sacral resection) reconstructed by hemipelvic allograft and THA. Five patients had Type II acetabular resections, reconstructed with structural allograft, roof ring and THA.

Osteosarcoma and chondrosarcoma were the most frequent tumours. All patients required walking aids. In the hemipelvic group there were two early deaths (peri-operative haemorrhage and aplastic anaemia). In seven patients (37%) the allograft remained intact without infection but three required revision THA for loosening. For these seven patients the functional outcome scores were TESS 64%, MSTS87 17/35 and MSTS93 of 45% (mean fifty-two months.). There were nine cases of deep infection (47%) with three patients maintaining a functional implant. The nineteenth patient was revised following allograft fracture.

In the Type II acetabular group, three patients had no complications, and two patients dislocated. The average scores were TESS 78%, MSTS87 21/35 and MSTS93 64% (mean fifty-five months).

Correspondence should be addressed to Cynthia Vezina, Communications Manager, COA, 4150-360 Ste. Catherine St. West, Westmount, QC H3Z 2Y5, Canada