PROXIMAL FEMORAL ALLOGRAFT FOR REVISION ARTHROPLASTY OF THE HIP



Abstract

We reviewed and discussed the results of one hundred and fifty-five proximal femoral allografts for revision total hip replacement at an average of eleven years (range , five to twenty years).We looked at graft survivorship, functional results, radiographic assessment and complications. We concluded that this is an excellent technique for restoration of bone stock in the multiplied revised hip.

To review the results of revision hip replacement with use of a proximal femoral allograft (PFA) to restore femoral bone stock.

Between 1983 and 1998 a PFA – prosthetic composite was used to revise two hundred and twenty-seven hips in two hundred and ten patients. Of these two hundred and ten revisions involved an allograft longer than 8 cm. The average age of the patients at the time of revision was sixty-six years. The average number of previous total hip replacements was 2.2. Each patient was assigned a SF-12 score and a Short WOMAC Score. Radiographic assessment for trochanteric union, allograft-host union, component stability, graft fracture and resorption was performed.

At an average of 11.2 years ( range, five to twenty years) after the revision, one hundred and eighty-five patients were alive, twenty-five patients had died and thirty were unavailable for follow-up. SF-12 and short WOMAC scores are still being calculated at the time of abstract submission. 4.4% of hips failed due to infection with 50% being successfully revised. Aseptic loosening of the construct occurred in 3.9% and 78% of these were revised at the time of follow-up. Nonunion of the allograft-host junction occurred in 4.8% and dislocation in 8.4%. Success was defined as a stable implant and no need for additional surgery at the time of follow-up. Success was noted in 84% of available cases.

At an average of eleven years revision hip arthroplasties with a PFA are performing very well. This technique remains an excellent alternative when confronted with femoral bone loss in the revision hip setting.