CORRECTION OF TIBIAL MALUNION AND NONUNION WITH SIX AXIS ANALYSIS DEFORMITY CORRECTION USING THE TAYLOR SPATIAL FRAME



Abstract

To determine the effectiveness of six-axis analysis deformity correction using the Taylor Spatial Frame for the treatment of post-traumatic tibial malunions and non-unions, the study design was a retrospectively reviewed, consecutive series. Mean duration of follow-up: 3.2 years (range 2–4.2 years). All patients had been referred to a tertiary referral centre for deformity correction. Eighteen patients were included in the study (11 mal-unions and 7 nonunions). All deformities were post-traumatic in nature. The mean number of operations prior to the application of the spatial frame was 2.6 (range 1–6 operations). All patients completed the study. Six-axis analysis deformity correction using the Taylor Spatial Frame (Smith & Nephew, Memphis, TN) was used for correction of post-traumatic tibial malunion or nonunion. Nine patients had bone grafting at the time of frame application. One patient with a tibial plafond fracture simultaneously had deformity correction and an ankle fusion for a mobile atrophic nonunion. Two patients had infected tibial nonunions that were treated with multiple debridements, antibiotic beads, and bone grafting at the time of spatial frame application. A rotational gastrocnemius flap was used to cover a proximal third tibial defect in one patient. The average length of time the spatial frame was worn, time to healing, was 18.5 weeks (range 12–32 weeks). The main outcome measurements involved assessment of deformity correction in six axes, knee and ankle range of motion, incidence of infection, and return to preinjury activities.

Results: Seventeen of the 18 patients treated with the Taylor Spatial Frame, with adjunctive bone graft as necessary, achieved union and significant correction of their deformities in six axes, i.e. coronal angulation and translation, sagittal angulation and translation, rotation, and shortening. Fifteen of the 18 patients returned to their pre-injury activities at last follow-up.

Conclusion: Six-axis analysis deformity correction using the Taylor Spatial Frame is an effective technique in treating post-traumatic malunions and nonunions of the tibia, with several advantages over previously used devices.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom