Full Access

BACTERIAL BIOFILM AND FRACTURE NON-UNION: ANTIMICROBIAL SUSCEPTIBILITY OF BACTERIA ISOLATED FROM RETRIEVED INTRAMEDULLARY NAILS



Abstract

The first aim of the study was to investigate if bacteria were implicated in non-union of fractures of the tibia and femur, which had been treated with intramedullary nailing. The second aim was to evaluate the antimicrobial susceptibility of bacteria isolated from the retrieved intramedullary nails.

Forty intramedullary nails removed from tibial and femoral fractures were retrieved for the purpose of the study. Twenty of these nails were from fractures, which had successfully united and 20 were removed from fractures which had failed to unite prior to further operative intervention. There was no evidence of clinical infection in either of the two groups. The nails were subjected to ultrasound in the research laboratory to dislodge adherent bacteria formed as biofilm from the surface of the nail. Using both standard culture techniques and non-culture techniques (Immunofluorescence microscopy and PCR analysis) any dislodged bacteria were isolated and identified.

Isolated bacteria were tested for antimicrobial susceptibility to commonly used antibiotics in orthopaedic practice according to NCCLS guidelines.

Bacteria were detected in 15 out of 20 [75%] of the nails removed from fractures, which had developed a non-union, and in 5 out of 20 [25%] of fractures that had united, using both standard culture techniques and non-culture techniques. The bacterial isolates identified were mainly Staphylococcus epidermidis and the Gram-positive anaerobe Proprionibacterium acnes.

Vancomycin was the most effective antibiotic, with 2 out of 34 [6%] isolates being resistant. Erythromycin was the least effective, with 21 out of 34 [62%] isolates being resistant. Based on overall Minimum Bactericidal Concentrations at which 90% of all strains were killed, Vancomycin was the most active bactericidal agent tested followed in decreasing order by fucidic acid, ciprofloxacin, gentamicin, cefamandole and erythromycin.

Bacteria were detected more commonly in the fracture non-union group than in the union group [p< 0.01]. Of the antibiotic agents tested Vancomycin was the most effective and Erythromycin was the least effective.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom