header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

TREATMENT OF COMPLEX, UNSTABLE, INTRA-ARTICULAR FRACTURES OF THE DISTAL RADIUS WITH A LOW PROFILE AO PI-PLATE



Abstract

This study investigates the efficacy of the AO Pi-plate in the treatment of complex, unstable, intra-articular fractures of the distal radius.

A retrospective study of 17 patients was carried out who underwent open reduction and internal fixation for dorsally displaced, intra-articular fractures of the distal radius using the AO Pi-plate. All patients were assessed clinically and radiologically post-operatively. The final functional outcome was assessed using the Gartland & Werley scoring system.

The average follow-up period was 34.3 months. 94% (16 patients) of the fractures were classified as AO type C fractures. The wrist movement was restored to a near normal range in all cases. The mean grip strength was 67% of the uninjured hand. The functional outcome as measured by the Gartland & Werley scoring system showed excellent and good results in 88% of the patients. Radiographic assessment revealed an average articular step-off of 0mm post-operatively. The implant removal rate was 29% (5 patients) and the main reason for that was extensor tenosynovitis.

Conclusion: Our study demonstrates that although the functional outcome after using the Pi-plate for complex distal radius fractures is good, there is a significant incidence of extensor tenosynovitis. We recommend that the implant is best used for Type C fractures and be removed electively after fracture union.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom