SONOGRAPHIC EVALUATION OF THE TREATMENT OF IDIOPATHIC CLUBFOOT ACCORDING TO PONSETI

7th Congress of the European Federation of National Associations of Orthopaedics and Traumatology, Lisbon - 4-7 June, 2005



Abstract

Background: The aim of this study was to evaluate Ponseti’s method of clubfoot management objectively and quantitatively by using ultrasound.

Methods: 22 newborns with 39 club feet were studied sonographically. Ultrasound examinations of all club feet were performed three times during the treatment according to Ponseti: at birth (1st measurement), one day before performing the percutaneous tenotomy of the Achilles tendon (2nd measurement) and 3 weeks after the operation (3rd measurement). In order to prove sonographic changes during the treatment precisely and quantitatively four angles (TnCe, TnMT1e, CaCue, TTd) were measured.

Results: Statistical analyses by using student’s t-test were conducted. The results are expressed as the means SD. At the first measurement means for TnCe were 19,41 (SD 11,71), for TnMT1e 15,21 (SD 10,32), for CaCue -6,49 (SD 7,14) and for TTd 33,38 (SD 10,60). At the second measurement means for TnCe were -6,93 (SD 3,96), for TnMT1e -12,24 (SD 4,76), for CaCue -4,00 (SD 5,24) and for TTd 28,66 (SD 6,38). At the third measurement means for TnCe were -7,86 (SD 5,47), for TnMT1e -12,97 (SD 5,69), for CaCue -1,45 (SD 2,05) and for TTd 18,08 (SD 2,75). At the 3rd measurement all angles showed values within the 95% confidence intervals of normal feet. All differences approached high significance (p< 0,0001).

Conclusion: During the treatment of idiopathic club-foot according to Ponseti the sonographically obtained measurements showed a significant improvement of all angles. Therefore this ultrasound technique can be used to evaluate the Ponseti method objectively and to compare one treatment to another.