THESSALY TEST: DIAGNOSTIC ACCURACY OF A NEW CLINICAL TEST FOR EARLY DETECTION OF MENISCAL TEARS

7th Congress of the European Federation of National Associations of Orthopaedics and Traumatology, Lisbon - 4-7 June, 2005



Abstract

Background: Clinical tests used for the detection of knee meniscal tears do not present acceptable diagnostic sensitivity and specificity values. Diagnostic accuracy is improved by arthroscopic evaluation or performing magnetic resonance imaging (MRI) tests. The objective of this study was to evaluate the diagnostic accuracy of a new dynamic clinical examination test for the detection of meniscal tears.

Methods: Two hundred and thirteen symptomatic patients with recent knee injuries who all were clinically examined, had MRI tests and underwent arthroscopic surgery and 197 asymptomatic volunteers who all were clinically examined and had MRI tests of their normal knees were included in this study. For clinical examination the medial and lateral joint line tenderness test, McMurray test, Apley compression and distraction test, Thessaly test at 5° and Thessaly test at 20° of flexion were used. For al clinical tests sensitivity, specificity, negative predictive value and diagnostic accuracy rates were calculated against arthroscopic and magnetic resonance imaging data.

Results: Thessaly test at 20° of flexion showed a high diagnostic accuracy rate at the level of 94% and a low number of false negative recordings in detecting tears of both the medial and lateral meniscus. Other traditional clinical examination tests, with the exception of joint line tenderness which presented a diagnostic accuracy rate of 88% in detecting lateral meniscal tears, showed inferior rates.

Conclusions: Thessaly test at 20° of flexion can be safely used as a first line screening clinical test for the detection of meniscal tears reducing the need and the cost of modern magnetic resonance imaging methods.

Theses abstracts were prepared by Professor Roger Lemaire. Correspondence should be addressed to EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.