header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

PERCUTANEOUS DYNAMIC HIP SCREW

7th Congress of the European Federation of National Associations of Orthopaedics and Traumatology, Lisbon - 4-7 June, 2005



Abstract

We present the results of a technique of dynamic hip screw insertion through a very small incision, typically 2.5cm.

Method: The technique is performed using a standard dynamic hip screw set and requires no additional equipment. We compared the results to those of an age and sex matched group who had undergone the operation through a traditional approach. We compared the time spent in theatre, the pre and post-operative haemoglobin concentration, haematocrit, and prevalence of wound infection.

Results: 13 consecutive intertrochanteric hip fractures were treated with a dynamic hip screw and 4-hole plate by one surgeon using the percutaneous technique. There were 9 females and 4 males with a mean age of 84 years (range 62 to 96 years).

The mean post-operative drop in haemoglobin concentration in the percutaneous group was 2.2 g/dl (range 0 to 4.4 g/dl) compared to 3.5 g/dl (range 1.2–5.4) in the control group (p=0.014). The mean haematocrit drop was 0.07 (range 0 to 0.12) in the percutaneous group compared to 0.10 (range 0.03 to 0.17) in the control group (p=0.017)

The mean theatre time with the percutaneous technique was 57 minutes (range 40–75 minutes) and in the control group, 60 minutes (range 30–95). There were no wound problems.

Conclusion: To our knowledge, this technique has not been previously reported. The percutaneous technique offers a better clinical outcome at no extra expense and warrants further evaluation in a larger study

Theses abstracts were prepared by Professor Roger Lemaire. Correspondence should be addressed to EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.