header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

IN VIVO ROTATOR CUFF BLOOD FLOW MEASUREMENT USING LASER DOPPLER FLOWMETRY



Abstract

Introduction: Laser Doppler Flowmetry (LDF) is an established technique for the measurement of perfusion in tissues, which has been applied in animal and human studies. Despite many studies the implications of perfusion and blood flow abnormalities in the rotator cuff (RC) in vivo are not clearly understood. This study aims to assess the blood flow in the normal and diseased RC using Laser Doppler Flowmetry (LDF) technique.

Methods: With Ethics approval and informed consent patients undergoing arthroscopy for impingement or cuff tear (diseased cuff) or for shoulder instability (normal cuff) were recruited. Following diagnostic arthroscopy and bursoscopy measurements of the blood flux in the RC using the LDF were made at 6 points. Five of these were in the cuff over a 4 cm2 area from the insertion at the greater tuberosity (A,E – @ Tuberosity level, C-Muscelotendinous junction, B,D – between the two) and one (F) in the deep surface. Diseased RC were subgrouped into mild (B1), moderate (B2) and severe (B3- cuff tear) impingement grades (Copeland-Levy Classification). The arthroscopy, grading, and probe placement were made by the two senior authors. LDF flux (unit of measurement of the perfusion – LDFf) was recorded over 30 seconds at each measurement point. The mean of these readings was calculated.

Results: 56 patients were recruited. 35 Males (62.5%) and 21 Females (37.5%).

336 measurements were recorded.

The observed mean LDFf was 32.8 (27.4–38.1; 95% CI) , 25.4 (22.4–28.5) and 43.1 (37.8–48.4; 95% CI) For Normal, Impingement and Tear cases, respectively (p< 0.0001, One-way ANOVA).

The LDFf was lowest in the Impingement without tear grade (B2) with a statistically significant increase at the edges of a cuff tear.

Conclusion: Preliminary recordings of LDF show changes are in keeping with current knowledge of the pathology. LDFf decreases with advancing impingement, being least affected in the musculotendinous junction. There is a substantial increase in LDFf at the edges of RC tears. This might reflect an attempted reparative response.

The abstracts were prepared by Ms Orah Naor. Correspondence should be addressed to Israel Orthopaedic Association at PO Box 7845, Haifa 31074, Israel.