header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

CUSTOMISED HINGED KNEE REPLACEMENTS AS A SALVAGE PROCEDURE FOR FAILED TOTAL KNEE ARTHROPLASTY



Abstract

Purpose: To assess the outcome of customised hinged knee replacements when used to salvage catastrophically failed knee replacements in elderly patients.

Methods: Since 1993, 30 of the 280 (10.7%) revision knee replacements at the Avon Orthopaedic Centre, Bristol have used Endo customised hinged knee pros-theses (21 rotating, 9 fixed) for salvage of limb threatening situations in elderly patients. All were prospectively recorded and regularly reviewed. The average age was 75 years with a predominance of females. Surgical indications were 22 periprosthetic fractures (with or without aseptic loosening), 5 massive aseptic osteolyses, and 3 deep infections.

Results: The mean length of postoperative hospital stay was just 14.6 days and all patients were discharged walking with aids. At follow up (mean 3.0 years, range 0.5–9.3 years) 9 patients had died with their prostheses in situ and functioning. 2 had undergone amputation for recurrent sepsis and 2 had received further surgery for septic problems. 2 patients required further surgery for prosthetic disarticulation and one patient had successful on table vascular repair. 25 patients had mid or long term follow up. Their mean American Knee Scores (AKS) were 69.8 for knee and 35.6 for function (maximum 100), with a mean total knee flexion of 83 degrees. Mean Oxford knee scores (OKS) and WOMAC scores (both scored between 12 and 60 with low score indicating less difficulties) were 34.0 and 30.5 respectively.

Conclusions: Customised hinge revision knee replacements gave extremely rapid rehabilitation and hospital discharge which justified the high prosthetic cost. Complications were high but at mid and long-term review, no prostheses had failed from an aseptic cause and most of the knees of this challenging group were providing both stability and flex

Correspondence should be addressed to Roger Smith, Honorary Secretary, BASK c/o Royal College of Surgeons, 35 – 43 Lincoln’s Inn Fields, London WC2A 3PN