REVISION TOTAL HIP REPLACEMENT FOR RECURRENT DISLOCATION BY A SINGLE SURGEON



Abstract

Background: Dislocation after total hip replacement (THR) is a significant concern with the increased number of THR carried out all over the world, although there has been a substantial lack of information regarding revision THR for instability in literature.

Purpose: The purpose of this study was to evaluate the effectiveness of operative treatment for recurrent dislocation after THR.

Material and methods: One hundred and eleven cases were treated operatively for recurrent dislocation after THR by a senior author (BMW). Group A; 104 cases were operated with change of either or both of components, a socket and a stem. Twenty-two mm head was used in 90 cases (A-1), 32 mm head in twelve (A-2), and 36 mm head in two (A-3). Group B; only modular head was changed in one case. Group C; augmentation device was applied on a cup in six cases. The average follow-up period was 6.2 years (range, 1 to 21 years).

Results: Group A-1; twelve cases (13%) required further operations for instability (N=90). Group A-2; one case (8.3%) was converted to Girdle-Stone for recurrent dislocation (N=12). Group A-3; one of them was revised for periprosthetic fracture (N=2). Group B; the case survived at the follow-up of 3.3 years (N=1). Group C; two cases (33%) were revised for dislocation (N=6).

Conclusion: We reported the largest series of revision THR for recurrent dislocation by a single surgeon with a considerable length of follow-up periods. Revision THR with change of components was an effective treatment for recurrent dislocation after THR.

The abstracts were prepared by Mr Peter Kay, Editorial Secretary. Correspondence should be addressed to British Hip Society, The Hip Centre, Wrightington Hospital, Appley Bridge, Wigan, Lancashire WN6 9EP.