SAFETY AND EFFICACY OF PNEUMATIC COMPRESSION WITH FOOT-PUMPS FOR PROPHYLAXIS AGAINST DEEP VEIN THROMBOSIS AFTER TOTAL HIP JOINT REPLACEMENT. A RANDOMIZED CLINICAL TRAIL



Abstract

Although a number of agents have been shown to reduce the risk of thromboembolic disease, their use in total hip replacement (THR) remains controversial. Uncertainty exists regarding the safety of chemical prophylaxis as well as the choice of the most effective agent. Previous studies suggested that pneumatic compression with foot-pumps provide the best balance of safety and effectiveness, however too few patients were investigated in randomised clinical trials to draw evidence-based conclusions.

The purpose of this randomized clinical trial was to compare the safety and efficacy of pneumatic compression with foot-pumps versus low-molecular-weight heparin (LMWH) for prophylaxis against DVT.

Inclusion criteria were hip osteoarthritis and age less than 80 years. Exclusion criteria were history of thromboembolic disease, heart disease, and bleeding diatheses. 216 consecutive patients were considered for inclusion in the trial and were randomized either for management with LMWH (Fraxiparin, Sanofi-Synthelabo, France) or with the A-V Impulse foot-pump (Orthofix Vascular Novamedix, UK). Patients were monitored for DVT using serial duplex sonography and phlebography.

DVT was detected in 3 of 100 patients managed with the foot-pump compared with 6 of 100 patients who received chemical prophylaxis (p< .05). Sixteen patients did not tolerate continuous use of the foot-pump and were excluded from the study. The average postoperative drainage was 259ml in the foot-pump group and 328ml in the LMWH group (p< .05). Patients with foot-pump had less swelling of the thigh (10mm compared with 15mm) (p< .05). The patients of the foot-pump group had less postoperative oozing and bruising than did those who had received LMWH. One patient developed heparin-induced thrombocytopenia.

This study confirms the safety and efficacy of mechanical prophylaxis of DVT in THR. Some patients cannot tolerate the foot-pump.

The abstracts were prepared by Jean-Claude Theis. Correspondence should be addressed to him at Department of Orthopaedic Surgery, Dunedin Hospital, Private Bag 1921, Dunedin, New Zealand.