header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

O1036 UNCEMENTED FEMORAL REVISION ARTHROPLASTY USING THE MRP-TITAN STEM – RESULTS OF 280 CASES FOLLOWED FOR 1 T0 8 YEARS



Abstract

Aims: Prospective multi-center study to evaluate the mid-term results of 280 uncemented femoral stem revisions using the modular MRP-Titan system. Methods: 273 patients with 280 MRP-Titan systems, follow-up for a mean time of 3 years (1 to 8 years). Harris hip score for clinical evaluation, bony defect classification according to Paprosky [163 cases (58%) with type 2B, 2C and 3]. Results: Three aseptic loosenings (1%), three septic loosenings (1%), one additional re-revision because of periprosthetic fracture. Postoperative dislocations occurred in 23 cases (8%), 17 of these (6%) were managed by closed or open reposition without changing the implant. In 6 cases (2%) the antetorsion angle of the modular prosthesis neck was altered. Harris hip score: 38 points preoperatively, 85 points at the last follow-up postoperatively. In 18 cases (6.4%) radiolucient lines were seen, but with no progression and no migration of the stems. The overall survival-rate after 8 years of follow-up was 92%. Conclusions: The modular MRP-Titan system has proven to be valuable in quite problematic cases of hip revision arthroplasty with extensive femoral defects. The system allows intraoperative adaptation of implant length and antetorsion angle to the actual situation, a feature not provided by non-modular femoral revision implants.

Theses abstracts were prepared by Professor Dr. Frantz Langlais. Correspondence should be addressed to him at EFORT Central Office, Freihofstrasse 22, CH-8700 Küsnacht, Switzerland.