Abstract

A previous study done in our unit showed good results in terms of union, stability and function following 2-suture repair of proximal humeral fractures. Healing took place usually with a mild degree of varus angulation but one failure of this technique when the fracture slipped into varus prompted us to re-evaluate our technique. The addition of a third (lateral) suture to the repair has been used as routine following this.

A prospective series of 24 patients with displaced Neer 2 and 3 part proximal humeral fractures was studied. The patients were reviewed at a mean of 22.5 months post fixation. The patients were reviewed clinically and graded according to the Constant Shoulder Score to assess range of movement, power, function and pain. This was compared to the contralateral uninjured shoulder.

Radiographic evaluation of fracture union, avascular necrosis and malunion was performed, and any complications of treatment were noted.

There were 24 2- and 3-part fractures. All the fractures united with no radiological evidence of avascular necrosis. At follow-up there was a mean Constant Score of 71.05 compared with a mean score of 84.5 on the uninjured contralateral shoulder. Active abduction of > 120° was achieved in 9 patients. Intraoperative stability in the varus/valgus plane was noted to be better.

All patients were satisfied with the results; the problem of instability in the coronal plane has not been a problem and the fractures have healed with no varus mal-union. There have been no additional complications with this technique compared to the 2-suture method.

We have successfully achieved stability after open reduction and suture fixation of 2- and 3-oart fractures of the proximal humerus. Following one case of varus instability using a 2 suture technique,

We have routinely supplemented this with a third (lateral) suture. There have been no additional complications using this method, the angulation of the fractures once healed are improved and none of the repairs have had a problem with varus slip.

These abstracts were prepared by Mr Cormac Kelly. Correspondence should be addressed to him c/o British Orthopaedic Association, Royal College of Surgeons, 35-43 Lincoln’s Inn Fields, London WC2A 3PN.