PREOPERATIVE BONE STOCK AND IMMEDIATE POSTOPERATIVE CEMENT-BONE INTERFACE IN ONE STAGE REVISION TOTAL HIP REPLACEMENT FOR DEEP INFECTION



Abstract

Purpose: The purpose of this study was to assess preoperative bone stock and immediate postoperative cement-bone interface as factors affecting infection control and mechanical outcome after one stage revision total hip replacement (THR) for deep infection.

Material and methods: This study included 115 cases which satisfied following conditions; a) One stage revision THRs for deep infection were carried out by a single surgeon (BMW). b) Follow-up of more than five years was possible. c) Complete series of radiographs were available including preoperative, immediate postoperative and the latest follow-up ones. Preoperative bone stock was classified into four grades (Grade 0: No bone loss, Grade 1: Demarcation, Grade 2: Localized cavitation, Grade 3: Significant bone loss). Immediate postoperative cement-bone interface was also graded into four categories (Grade A: White-out, obscure interface, Grade B: Clear line, no measurable gap, Grade C: Gap> 1mm, Grade D< 1mm). These two factors were analysed in view of infection control and mechanical survival of implants after surgery.

Results: Preoperative bone stock did not show significant influence on infection control while it affected mechanical outcome. Immediate postoperative cement-bone interface was an affecting factor for not only mechanical survival of implants but cure of infection.

Conclusion: Preoperative bone stock and immediate postoperative cement-bone interface were assessed as influential factors in one stage revision THR for deep infection. There was a good chance of cure of infection even in cases with significant bone loss. Good cement fixation appeared to be important in view of infection control as well as mechanical survival of implants.

Theses abstracts were prepared by Mr Peter Kay. Correspondence should be address to him at The Hip Centre, Wrightington Hospital, Appley Bridge, Wigan, Lancashire WN6 9EP.