header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

CAN A SEROLOGICAL MARKER BE USED TO DIFFERENTIATE BETWEEN SEPTIC AND ASEPTIC LOOSENING OF TOTAL HIP REPLACEMENTS?



Abstract

Introduction: We have investigated the accuracy of a serological marker to distinguish between septic and aseptic loosening of Total Hip Replacements (THR). We present the preliminary results of our on-going prospective study.

Methods: After obtaining Ethical Committee approval, 46 patients were collected in 3 groups; “control” primary THR, revision THR for aseptic loosening, and revision THR for infection. Serum IgG responses to an exocellular bacterial antigen (Lipid S) were determined by enzyme-linked immunosorbent assay (ELISA).

Results: Our results show that the test can accurately differentiate between the patients with infected joint replacements and the control group. The test, to date, has a specificity of 93% and a sensitivity of 100%.

Clinical Relevance: This simple and cheap test can reliably assist in the accurate evaluation of a painful hip arthroplasty, and planning for revision surgery. It will also be useful in the management of patients in whom the microbiology results are either negative or based on a single isolate of an organism, which may be either a contaminant or a possible pathogen. This, inturn, would have implications on financial costs and the optimum use of available resources.

Theses abstracts were prepared by Mr Peter Kay. Correspondence should be address to him at The Hip Centre, Wrightington Hospital, Appley Bridge, Wigan, Lancashire WN6 9EP.