header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

DIGITAL ASSIST SYSTEM WITHOUT IMAGES FOR TOTAL KNEE ARTHROPLASTY: MULTICENTRIC STUDY OF 821 KNEES



Abstract

Purpose: The purpose of this study was to conduct a multicentric comparison of total knee arthroplasty using the conventional technique versus digitalized navigation.

Material and methods: A prospective comparative study was conducted in five centres in 821 patients using the same implant (Search®, Aesculap, Chaumont): 555 procedures with the Orthopilot® navigation system (Aesculap, tutligen, group 1) and 266 conventional procedures, group 2). Radiographic results were analysed by an independent investigator who examined telemetric images obtained three months after surgery.

Results: The mechanical femorotibial axis was within desired limits (3° frontal deformation) in 88.6% of the knees in group 1 and in 72.2% of the knees in group 2 (p< 0.001). The rate of unacceptable implantations (> 5° deviation) was 2.5% in group 1 and 9.8% in group 2).

Frontal orientation of the femoral component was satisfactory in 89.4% of the knees in group 1 and in 77.1% in group 2. Sagittal orientation of the femoral component was satisfactory in 75.5% of the knees in group 1 and in 70.7% of the knees in group 2. Frontal orientation of the tibial component was satisfactory in 91.9% of the knees in group 1 and in 83.5% of the knees in group 2. The sagittal orientation of the tibial piece was satisfactory in 81.3% of the knees in group 1 and in 69.9% of the knees in group 2. Optimal implantation, considering all criteria studied, was achieved in 275 patients (49.5%) in group 1 and in 82 patients (30.8%) in group 2 (p< à.001). Ther was no difference in results between centres.

Discussion: Computer-assisted navigation facilitated prosthesis implantation with the desired orientation in comparison with manual instrumentation. The number of unacceptable implantations was significantly lower. After a short learning curve, the reliability of this system has proven very satisfactory, facilitating its use since this study.

The abstracts were prepared by Docteur Jean Barthas. Correspondence should be addressed to him at Secrétariat de la Société S.O.F.C.O.T., 56 rue Boissonade, 75014 Paris.