ANTERIOR CRUCIATE LIGAMENT (ACL) RECONSTRUCTION WITH HAMSTRINGS: AN IN VIVO STUDY.



Abstract

Introduction: The aim of this study was to evaluate whether a guiding pin for a femoral tunnel could be positioned through the tibial tunnel into the center of the anatomical ACL attachment.

Material and Methods: We studied 77 knees who underwented arthroscopic ACL reconstruction with hamstrings. The femoral tunnel was drilled through an antero-medial portal at the center of the anatomic insertion at about 10 resp. 2 o’clock position. Tibial tunnel (mean diameter 7.55 ± 0.54 mm ) was drilled at 90° of knee flexion. The aiming point was on a line, being a “prolongation” of the posterior border of the anterior horn of the lateral meniscus and at exactly 60% of the distance from the end of the anterior horn of the lateral meniscus and the medial tibial spine. Then, through the tibial tunnel, a 4mm offset femoral drill guide was positioned as close as possible to the femoral tunnel and a 2.5 mm guide wire was drilled. The position of the guide wire was photographed arthroscopically and the deviation was measured as distance between the center of the femoral tunnel and guide wire.

Results: The mean angle of the tibial tunnel in the coronar plain was 27,53° and in the sagittal plain 25,84°, both according to the longitudinal axis of the tibia. In 74 knees ( 96. 1 % ) the guidewire did not reach the femoral tunnel. Only in 3 knees it reached the superomedial edge of the femoral tunnel. The mean deviation was 4.50 ± 1.54 mm (p = 0.00000004 ). No statistical relationship was found between deviation and tibial tunnel inclination angles or tibial tunnel diameter.

Conclusion: Transtibial femoral tunnel drilling did not reach the anatomic side of the ACL insertion in most of the cases, even with larger tibial tunnels (for hamstring grafts up to 8.5 mm). Therefore we recommend tibial tunnel drilling through the anteromedial portal.

Correspondence should be addressed to 8 Martiou Str. Panorama, Thessaloniki PC:55236, Greece.